Files
simple-aircraft-manager-rails/app/models/ad_compliance.rb
T
rickyandClaude Opus 5.5 f94ccee99b Calculate next-due for AD compliance and inspections from their rules
- AD compliance "next due at tach reading" is prefilled from the AD's
  hour recurrence (hours at compliance + interval), recalculates live as
  the AD/date/hours change, keeps a typed-in override, and is filled
  server-side when left blank.
- Live "Next due" preview on AD compliance and inspection record forms
  (hours and/or end-of-month date, whichever comes first), mirroring
  Compliance.next_due so preview and status agree.
- Reject an interval entered as the next-due reading (e.g. "100" for
  "every 100 hours"), which made a complied AD show as overdue.
- ADs table shows hours remaining next to the due tach reading.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-11-05 07:24:28 -05:00

41 lines
1.7 KiB
Ruby

class AdCompliance < ApplicationRecord
belongs_to :airworthiness_directive
belongs_to :aircraft, optional: true
belongs_to :component, optional: true
belongs_to :logbook_entry, optional: true
belongs_to :inspection_record, optional: true
validates :date_complied, :compliance_notes, presence: true
validate { errors.add(:base, "Must belong to an aircraft or component") unless aircraft_id || component_id }
validate :next_due_is_a_future_reading
before_validation :fill_next_due, if: -> { next_due_at_time.to_d.zero? }
scope :recent_first, -> { order(date_complied: :desc, created_at: :desc) }
# Prefill next_due_at_time from the AD's hour recurrence (hours at compliance
# + interval). Only fills a blank/zero value, so a typed-in reading wins.
def fill_next_due
return if permanent? || airworthiness_directive.nil?
base = aircraft_hours_at_compliance || aircraft&.tach_time
due = Compliance.next_due(airworthiness_directive.due_rule, date: date_complied, hours: base)
self.next_due_at_time = due[:hours] if due[:hours]
end
def self.for_aircraft(aircraft)
where(aircraft_id: aircraft.id).or(where(component_id: aircraft.components.select(:id)))
end
private
# next_due_at_time is an absolute tach reading, not an interval. Catch the
# easy mistake of entering "100" for "every 100 hours".
def next_due_is_a_future_reading
due = next_due_at_time.to_d
return if permanent? || due <= 0
base = aircraft_hours_at_compliance || aircraft&.tach_time
return unless base && due <= base
errors.add(:next_due_at_time, "must be a tach reading after the compliance hours (#{base}). " \
"For “every 100 hours” enter #{base + 100}, not 100")
end
end